The NetApp FAS3050 filer delivers the performance, flexibility, and manageability essential for stable and productive IT storage infrastructure operations. As part of the unified NetApp architecture, FAS3050 filers support file services, FC SAN, IP SAN, and multiple network configurations, while offering scalability to higher performance systems with seamless, painless upgrades without requiring the "forklift" data migration needed by most other offerings currently on the market. Additionally, the FAS3050 fully extends the value of the FlexVol capabilities built into Data ONTAP 7G by increasing disk performance even for small data volumes. FlexVol technology can reduce storage management costs and increase customers' storage utilization by up to 50%, and when combined with the new SATA storage option, primary storage costs can be reduced by more than half. FAS30X0 Overview– download PDF | FAS3050 Technical Highlights | | Maximum RAID Group Sizes | RAID-6 FC-28 (26 data disks plus 2 parity disks) SATA-16 (14 data disks plus 2 parity disks) RAID-4 FC-14 (13 data disks plus 1 parity disk) SATA-7 (6 data disks plus 1 parity disk)
RAID-6+RAID1 or RAID4+RAID1 | | SAN Protocol Support | Fibre Channel Protocol (FCP) for SCSI (2Gb and 4Gb); fabric-attached and direct-attached; iSCSI | | File Service Protocol Support | NFS V2/V3/V4 over UDP or TCP, PCNFSD V1/V2 for (PC) NFS client authentication, Microsoft CIFS | | Other Protocol Support | HTTP 1.0, HTTP 1.1 virtual hosts | | LUNs | Up to 2,048 on FAS3070 and up to 1,024 on FAS3020 and FAS3050 | | FlexVol Volumes | Up to 500 per controller | | Volume/Aggregate Size | 16TB | | Snapshot Copies | Up to 127,000 | | Number of Supported Hosts | Up to 4 ports per controller configured as front-end (host) connectivity ports Up to 4 directly connected servers (per controller and per active/active configuration) Up to 256 SAN connected servers (per controller and per active/active configuration) | | Supported Configurations | Highly Available Controller Configurations Active/active controller with Controller Failover (CFO), active/active controller with stretch (non-switch) MetroCluster, active/active controller with Fabric Attached MetroCluster
Highly Available Back-End (Disk) Configurations Dual-path, Multipath HA Storage | | Reliability | Redundant hot-swappable controllers, cooling fans, power supplies, optics, and RJ-45 ports | | Management | Full-duplex 10/100/1000Base-T Ethernet onboard console, diagnostic LED/LCD, Remote LAN Management (RLM) Card, SNMP, telnet, SSH, HTTP, Web (SSL), host scripting, e-mail alerts | | Security | Virus Protection Authentication: Kerberos (MIT/Active Directory) Authorization: LDAP, NIS Auditing: File access logging Encryption: IPSec, SSL, SSH, SMB signing Role Based Access Control (RBAC) | | Scalability | FAS3050 | | | Active/Active Configuration | Single Controller | | Max. Raw Capacity | 168TB | 168TB | | Max. Number of Disk Drives | 336 | 336 | | Max. Drives per Back-End (Disk) FC Loop | 84 | 84 | | ECC Memory | 8GB | 4GB | | Nonvolatile Memory | 1GB | 512MB | | I/O | FAS3050 | | | Active/Active Configuration | Single Controller | | Onboard (fixed) Fibre Channel Ports (target or initiator) | 8 ports of 2Gb | 4 ports of 2Gb | | Onboard (fixed) GbE Ports | 8 | 4 | | Modular I/O Slots | 6 | 3 | | RAID-6 is the recommended configuration for drives greater than 144 GB. RLM module is an optional capability on FAS3050. | | I/O Card Support | FAS3050 | | | Active/Active Configuration | Single Controller | | Dual FC Disk Adapters (max.) | 6 | 3 | | Dual 4Gb FC Target Adapters (max.) | 4 | 2 | | Quad 4Gb FC Disk/Tape Adapters (max.) | 6 | 3 | | Dual FC -Tape Adapters (max.) | 6 | 3 | | Dual-port SCSI HBA | 6 | 3 | | Optional Network Connectivity (max.) Quad GbE TOE (copper) cards Single 10GbE TOE (fiber) cards Dual GbE (copper or fiber) cards Dual iSCSI (copper or fiber) host adapter |
4 4 6 6
|
2 2 3 3
| | Sofware | | Operating System | Network Appliance Data ONTAP | | Operating Systems Supported | Windows 2000, Windows Server 2003, Windows XP, Linux, Sun Solaris, AIX, HP-UX, Mac OS, VMware, ESX | | Software Features | Standard RAID manager, including RAID-6 (RAID-DP) Snapshot Fast Boot NIS DNS FilerView FlexVol FlexCache FlexShare Network Data Management Protocol (NDMP) Maintenance Center
| Licensed FlexClone MultiStore SnapMirror SnapRestore SnapDrive SnapManager for Microsoft Exchange SnapManager for Microsoft SQL Server SnapManager for Oracle Single Mailbox Recovery SnapVault SnapMover LockVault SnapLock Compliance SnapLock Enterprise SyncMirror MetroCluster NearStore Personality Option CommandCentral Storage Protection Manager Virtual File Manager - Enterprise Edition Virtual File Manager - Migration Edition File Storage Resource Manager SAN Manager Operations Manager ApplianceWatch for HP Openview ApplianceWatch for Tivoli
| | Storage Specifications | | Disk Shelves Supported (Fibre Channel, SATA) | DS14, DS14mk2 FC, DS14mk2AT Each w/14 low-profile slots for FC and SATA disk drives | | Disk Drive Support | Disks Supported on New Configurations FC-144GB, 300GB disks SATA-250GB, 500GB disks
Disks Supported for Legacy (Controller Upgrade) Configurations FC-36GB, 72GB, 144GB, 300GB disks SATA-250GB, 320GB, 500GB disks | | Disk Shelf Support | Shelves Supported on New Configurations Embedded Switched Hub (ESH) Embedded Switched Hub2 (ESH2) AT-FCX
Shelves Supported for Legacy (Controller Upgrade) Configurations Embedded Switched Hub (ESH) Embedded Switched Hub2 (ESH2) AT-FCX LRC | | Disk Drive Storage Shelf Interface | Fibre Channel-Arbitrated Loop (FC-AL) | | Power Supply/Cooling Fans | Dual, redundant, hot-pluggable, integrated power supply/fan assemblies (220V/110V) | | AC Power/Max. Current | 100 to 120VAC/3.95A; 200 to 240VAC/1.9A | | Thermal Rating | 1,215 Btu/hr (fully loaded shelf) | | Operating Acoustic Noise | 49 dBA sound pressure (LpA) @ normal operating conditions (at 22°C and at sea level) | | Dimensions (height/width/depth) | 3 EIA U (5.25", 13.3 cm)/19" IEC rack-compliant (17.6", 44.7 cm)/20" (50.85 cm) | | Weight | 77 lb (35 kg) fully loaded | | FAS3050 has PCI-x I/O slots. Protection Manager was previously known as Business Continuance Option Operations Manager was previously known as Data Fabric Manager (DFM). | | FC Switch Support- Tape/SAN | | Vendor | Model | | Brocade | Silkworm 2400/2800 (TapeSAN only) | | Brocade | Silkworm 3200/3250/3800/3850/3900/4100/12000/24000/200E | | McData | ES 3016/3032, Intrepid 6064/6140/ED-5000, Sphereon 3216/3232/4300/4400/4500/4700 | | Cisco | MDS 9120/9140/9216/9506/9509/9513 | | FC = Fibre Channel; LVD = Low Voltage Differential; | | NetApp Systems Cabinet | | 20A and 30A single phase cabinets.
20A Cabinet - Includes 4 power cords with NEMA L6-20 or IEC 309 or Australia AS/NZ53123-20 connectors
30A Cabinet - Includes 2 power cords with NEMA L6-30 or IEC 309 connectors | 20A Cabinet - a single controller and 13 DS-14 shelves; two controllers and 12 DS-14 shelves
30A Cabinet - a single controller and 12 DS-14 shelves; two controllers and 11 DS-14 shelves | | AC Power | 200 to 240VAC | | Current | Redundant power 20A Cabinet - Maximum 32A total 30A Cabinet - Maximum 24A total | | Dimensions (height/width/depth) | 78.75" (200 cm)/23.6" (60 cm)/37.4" (95 cm) | | Min. Clearances | 48" (122 cm) front and rear | | Shipping Height | 90.6" (230 cm) | | Weight (empty) | 275 lb (125 kg) | | FAS System Specifications | Active/Active Configuration | Single Controller Configuration | | AC and DC Power/Current (line voltage for standalone systems dependent on local power distribution; system cabinets are 200 to 240VAC only) | 100 to 240VAC, 7.66 to 3.50A, 50/60Hz
200 to 240VAC, 4.00 to 3.50A, 50/60Hz
48VDC, 14.8A, 710W | 100 to 240VAC, 3.83 to 1.75A, 50/60Hz
200 to 240VAC, 2.00 to 1.75A, 50/60Hz
48VDC, 7.4A, 355W | | Thermal Rating | 2430 Btu/hr | 1215 Btu/hr (note: Watts x 3.4129) | | Weight | 150 lb (68 kg) | 75 lb (34 kg) | | Height | 10.24" (26 cm), fits into 6U space | 5.12" (13 cm), fits into 3U space | | Width | 19" IEC rack-compliant (17.7", 44.9 cm) | | Depth | 24" (61 cm), 30" (76.2 cm) with cable management bracket | | Operating Temperature, Altitude, and Relative Humidity | 10° C to 40° C (50° F to 104° F); at = temperature) | | Non-operating Temperature and Relative Humidity | -40° C to 65° C (-40° F to 149° F); 10% to 95% relative humidity, non-condensing, in original container | | Operating Acoustic Noise | < 54 dBA sound pressure (LpA) @ normal operating conditions (at 22°C and at sea level) | | Min. Cabinet Clearances for Airflow | 10" (25.4 cm) in front, 12" (30.5 cm) in rear | | Min. Cabinet Clearances for Service | 30" (76.2 cm ) in front, 30" (76.2 cm) in rear | | Compliance | RoHS-compliant | | Safety/Emissions/Immunity | Safety: EN 60950, CE, CSA 60950, UL 60950, CB IEC60950-1 (all national deviations), EN60825-1, IRAM, GOST-R, BSMI
Emissions/Immunity: FCC Part 15 Class A, ICES-03, CE, MIC, VCCI, AS/NZS CISPR 22, EN55022, EN55024, EN61000-3-2, EN61000-3-3, CoC (South Africa), BSMI | For more information on Used NetApp Storage Arrays, please call us at (888) 786-2727 and ask for one of our Storage Consultants or email us at info@atlantixglobal.com.
|
|